Ocular Satellite DC Charging

Ocular Satellite DC Charger – Air Cooling Wall-Mounted Dispenser 300A

 

QUICK OVERVIEW

The Ocular Satellite DC Air Cooling Wall-Mounted Dispenser is a compact, space-efficient DC charging solution designed to integrate with the Satellite Base Station system. Ideal for constrained environments such as depots, basements, and commercial facilities, it delivers high-performance charging with a minimal footprint while maintaining full smart charging capabilities.

  • Up to 400kW
  • OCPP 2.0.1 & OCPP 1.6J
  • Wall-Mounted Design
  • 7 inch Touchscreen

  • Wall-mounted DC satellite dispenser for centralised charging system
  • Available in 250kW, 300kW, 375kW, and 400kW configurations
  • Supports CCS2, CCS1, CHAdeMO & GB/T (model dependent)
  • 150–1000V DC output range
  • Compact design ideal for space-constrained environments
  • 7” LCD touch screen interface
  • LED status indication with app integration
  • Ethernet connectivity
  • Multiple authentication methods (App, RFID, QR Code)
  • OTA software updates via web portal
  • IP55 rated enclosure for indoor/outdoor use
  • Designed for integration with Satellite Base Station system

Input Requirements: 

  • AC Supply System: Supplied via Satellite Base Station
  • Nominal Input Voltage: N/A (DC supplied from power cabinet)

Environmental Requirements: 

  • Ambient Temperature Range: -30 to 55°C
  • Storage Temperature: -30 to 80°C
  • Operating Altitude: ≤2000m

Mechanical Requirements: 

  • IP Rating: IP55
  • Cooling: Air-cooled
  • Mounting: Floor standing
  • Dimensions: 860 x 528 x 284 mm

Output Requirements:

  • Number of Outputs: 1
  • Output Power: 250kW / 300kW / 375kW / 400kW
  • Output Voltage: 150–1000V
  • Output Current: 250A / 300A / 375A / 400A

User Interface & Display Requirements: 

  • Display & Touch-Screen Size: 7″ Touch Screen
  • User Authentication: Mobile Application / RFID Card / QR Code
  • Metering Information: Consumption Units
  • Status Indication: LED / LCD / APP

Communication Requirements: 

  • Communication between EVSE and Central server: Via Base Station
  • Interface between Charger and CMS: Ethernet
  • Protocols: OCPP 1.6J & OCPP 2.0.1, ISO15118 (PnC & EIM), DIN70121, CHAdeMO 2.0, GB/T 27930

Protection & Safety Requirements: 

  • Executive Standard: EN IEC 61851-1, EN IEC 61851-23
  • Certifications: EN 61000-6 Series, EN IEC 61851-21-2, EN 301 489-1/-3, EN 300 330, EN 62479 RFID
  • Safety Parameters: Over Current, Under Voltage, Surge Protection, Leakage Protection, Short Circuit, Over Temperature